- Circuit Breakers[10]
- Wall Switches[6]
- Other Switches[1]
- Contactors[8]
- Relays[10]
- Other Motor Accessories[1]
- Other Electrical Equipment[2]
- Power Accessories[5]
- Electronic & Instrument Enclosures[5]
- Inverters & Converters[6]
- Power Distribution Equipment[5]
- Energy Meters[10]
- Other Roadway Products[1]
- Push Button Switches[10]
- Fuses[10]
- Fuse Components[1]
- Uninterrupted Power Supply (UPS)[1]
- Voltage Regulators/Stabilizers[7]
- Transformers[6]
- Other Wiring Accessories[1]
- Cable Ties[1]
- Cable Clips[1]
- Other Connectors & Terminals[1]
- Cable Glands[2]
- Fan Parts[1]
- Terminals[4]
- Hydraulic Tools[1]
- Alarm[1]
- Energy Saving & Fluorescent[1]
- Other Lights & Lighting Products[2]
- Other Electronic Components[1]
- Limit Switches[2]
- Contact Person : Mr. Ye Victor
- Company Name : CNC Electric Group Co., Ltd.
- Tel : 86-577-61989999
- Fax : 86-577-61891122
- Address : Zhejiang,Yueqing,Changcheng High-Tech Industrial Zone,North Baixiang
- Country/Region : China
- Zip : 325603
YCB AC Frequency Converter 50hz 60hz
YCB AC Frequency Converter 50hz 60hz
YCB100,YCB200 frequency converter use special control method to achieve driving with function of high torque, high precision and multi speed adjustment, it can meet the trend of high-performance of frequency converter. The anti-tripping performance is exceeding similar products and can used in environment of bad power grids,temperature and dust,and it greatly improve the reliability of product. YCB100,YCB200 frequency converter is the revolutionary products which integrate the customer's general demand,special demand and industrial demand in first time.The multi application function can supply high level of integrate solution for equipmentmanufacturing customers,it can reduce the system costs and improve system reliability,and satisfy customer's demands of lownoise,low. electromagnetic interference through optimization PWM control technology and integrated design of electromagnetic.
Environment and structure installation
Item | Destription | |
Environment | Using place | Indoor without direct sunlight,dust,corrosive gases,combustible gases, oil mist,water vapor, water or salt |
Altitude | 1000m | |
Ambient temperature | -10~+40(Use demoted if the ambient temperature is 40~50) | |
Humidity | 95%RH,no water condensation | |
Vibration | 9.5m/s (0.6g) | |
Storage temperature | -40~+70 | |
Structure | Protection level | IP20 |
Cooling method | Forced air-cooled with fan control | |
Installation | Wall-mounted,installed equipment cabinet |
YCB100 general technical data
Item | Description | |
Input | Rated voltage,frequency | Three phase 380V~440V,50Hz/60Hz |
Output | Allowed working voltage scope | Voltage: 320V~460V,voltage imbalance rate: 3%,frequency 5% |
Rated voltage | 380V | |
Rated frequency | 0~65Hz | |
Main control performance | Overload performance | G type:1 minute for 150% rated current,0.5 second for 200% rated current P type: 1 minute for 110% rated current,1 second for 150% rated current |
Speed adjust method | Flux Vector PWM regulator | |
Speed adjust | scope 1:100 | |
Starting torque | 0.50Hz of 180% rated torque | |
Working speed stable precision | ≤±5% rated synchronous speed | |
Frequency precision | Numerical setting: highest frequency ×0.01%, Simulation setting: highest frequency ×±0.02%, | |
Frequency resolution | Numerical setting: 0.01Hz Simulation setting: highest frequency ×0.1%, |
YCB200 general technical data
Item | Description | |
Input and Output characteristics | Input voltage scope | 380/220V±15% |
Input frequency scope | 67~63Hz | |
Output voltage scope | 0~rated output voltage | |
Output frequency scope | 0~600Hz | |
Peripheral interface characteristics | Programmable digital input | 4 ways input |
Programmable analog input | VI:0~10V input, CI:0~10V or 0~20mA input | |
Open collector output | 1 way output | |
Relay output 1 | Way output | |
Analog output 1 | Way output, can select 0/4~20mAo or 0~10V | |
Technical performance characteristics | Control method | NO PG vector control, V/F control |
Overload capacity | 60s for 150% rated current and 10s for 180%rated current | |
Starting torque No. | PG vector control: 0.5Hz for 150% rated torque | |
PG vector control: 1:100 | ||
Speed control precision | NO PG vector control: ±0.5% highest speed | |
Carrier wave frequency | 0.5K~15.0Hz | |
Functions | Frequency | Setting method digital setting, analog setting, serial communication |
Setting method | Setting, multi-speed, PID setting etc. | |
PID control function | May constitute closed-loop control system easily | |
Multi-speed control function | 8 speed control | |
Swinging frequency control function | Can achieve swinging frequency function with center frequency adjustable | |
Instantaneous power down non-stop function | Through the bus voltage control to achieve uninterrupted operation when power-down instantaneously | |
Speed tracking restart function | Achieve non-impulse start for rotating motor | |
JOG key function | Free multi-user-defined key | |
Automatic voltage regulation | When the voltage changes, it can automatically maintain a constant output voltage | |
Protect function | Protection of missing phase over current, over voltage, under voltage, overheating and overload |